Community Profile

photo

Pemendra Kumar Pardhi


Shri G. S. Institute of Technology & Science Indore

Last seen: 5日 前 2018 以来アクティブ

Statistics

All
  • 5-Star Galaxy Level 4
  • Revival Level 2
  • Solver
  • Thankful Level 1
  • Explorer
  • Personal Best Downloads Level 3
  • Knowledgeable Level 2
  • 3 Month Streak
  • First Review
  • First Submission
  • First Answer

バッジを表示

Content Feed

表示方法

質問


Debug Server Scripting (DSS) error:
Hello, i am trying to interface TMS320F2812 dsp trainer kit with MATLAB 2020b It successfully creates a .out file. However i...

約2ヶ月 前 | 0 件の回答 | 0

0

回答

回答済み
Model simulink block connection with different simscape
Dear You can connect single phase voltage source from simelectrical-specialized technology- source. In between port 1 and 2 a...

2ヶ月 前 | 1

回答済み
How to set universal bridge as inverter
Hi, Frank You can use universal bridge as a Inverter or PWM rectifier or uncontrolled rectifier For inverter you must select c...

4ヶ月 前 | 0

回答済み
Simscape powergui - Invalid dimension specified for input port
Hi Abd Al-Rahman Al-Remal This error occurs due to, you are providing 6 input signals on gate signal of each IGBT, moreover on...

4ヶ月 前 | 1

| 採用済み

回答済み
Simulink asynchronous generator voltage input clarification
Hello Dear Abd Al-Rahman Al-Remal The DFIG in wind energy conversion system worked as generator. Therefore it is able to...

4ヶ月 前 | 1

質問


Code Generation for TMS320F28379D using MATLAB With Repeating Sequence and Relational Operators block.
Hello, I am trying to generate the code from MATLAB 2020a for the LaunchPad TMS320F28379D microcontroller as shown in the attac...

4ヶ月 前 | 1 件の回答 | 0

1

回答

回答済み
Error in PWM Generator Vienna Rectifier
Dear Arkadeep Deb Please used datatype conversion with boolean in place of intiger 8 (int 8) I think it may creat a problems. ...

4ヶ月 前 | 0

回答済み
Can anyone help me to solve this error?
Dear Shankarao Rajasuriyan It is occur due to Numbers of signal input in the multiplication/division block After Mux block t...

4ヶ月 前 | 0

回答済み
Why MATLAB crashed while running PV based boost converter simulink model
Dear, This kind of problem rarely occurs. And it occurs due to improper design of system parameters ( Such as inductive or Cap...

4ヶ月 前 | 0

回答済み
Stator Flux Estimation of Induction Motor in real time
If any one suffer with above problems It is occurring due to DC ofset in sensed quantity ( it is due to sensor's inherently pro...

4ヶ月 前 | 0

| 採用済み

回答済み
can't connect source generator with controlled voltage source in matlab simulink
Both elements belong to different libraries. to connect both of them please use simulink to physical connector as attached fil...

6ヶ月 前 | 1

| 採用済み

質問


Data Plotting in a Single Figure
Dear all, I want to plot a single figure including four variable. I have a data as atteched file I want to plot a figure i...

6ヶ月 前 | 1 件の回答 | 0

1

回答

質問


Stator Flux Estimation of Induction Motor in real time
Hi, I am using TMS320F28379D LAUNCHPad for implementation of induction motor control and code is generated from MATLAB2019b. f...

10ヶ月 前 | 1 件の回答 | 0

1

回答

回答済み
What is wrong with my matlab codes? ( MATLAB) please help me!
Please replace the all * with .* for element wise product and in line no 31, you neet to replace t with wt

10ヶ月 前 | 0

| 採用済み

質問


Higher Order (6X6) Matrix Inverse with Variables
Hi, I want to obtained Inverse of higher order (6X6) matrix via matlab Matrix Like This Is it possible to obtained inverse...

11ヶ月 前 | 1 件の回答 | 0

1

回答

回答済み
Error: "Each physical network must be connected to exactly one Solver Configuration block. There is no Solver Configuration block connected to Physical Network with the following blocks..."
Dear, You have to recuired Solver Configuration block at grounding point as shown in attached file the Solver Configuration ...

12ヶ月 前 | 1

回答済み
I want to model 100KVA load operating at 0.9 power factor lagging. What should i set Active Power, QL and QC in load parameters?
Dear Syed Umaid Ali, as per your requirement Apparent power S= √(P^2+Q^2 ).....................................(1) And power...

約1年 前 | 0

| 採用済み

質問


Figure plote in MATLAB 2019b
Hi, I am ploting the figure on matlab 2019b in sub plot formate(more than one plote in single figure), whenever i set the possi...

約1年 前 | 1 件の回答 | 0

1

回答

回答済み
Warning: Matrix is close to singular or badly scaled ( simulink model with simscape blocks simpowersystems)
Dear Sreeraj This kind of error is occure whenever your simulink model having denomenator zero, If you are using for code genr...

約1年 前 | 0

回答済み
TI C2000 ADC Output
Dear Bilal Ahmad, The observed, scope signal is differ from actual signal that means your actual signal is 400Hz frequancy but ...

1年以上 前 | 0

回答済み
How to obtain the rotor side and grid side control of GRID connected DFIG based wind energy conversion system
Dear Sri Lakshmi, To devoloped control for DFIG based grid connected wind energy conversion system (WECS), please analysis as ...

1年以上 前 | 0

回答済み
how can I overcome on algebraic loop in simulink
Dear, Rashed, Basialy algebric loop error occure in simulink model whenever zero is come in denomenator part of any function. ...

1年以上 前 | 1

| 採用済み

回答済み
Power input fluctuating causes?
Power extraction from PV is dependent on controller. Actualy your inverter controller is responible to trac the MPPT, because ...

1年以上 前 | 0

質問


TMS320F28379D: Using MATLAB2018a to observed analog signal from DACOUTB pin
Hi, I am using hardware targate suport pakage for TIC2000, to implement control techniques on TMS320F28379D from MATLAB simulin...

1年以上 前 | 0 件の回答 | 0

0

回答

回答済み
How to open 2019b simulink models in 2019a version??
Dear, Dileepa B. S, For open to simulink model in MATLAB2019a, wchich is created in MATLAB2019b, For this, you can take help ...

1年以上 前 | 0

回答済み
voltage regulator design for solar under varying irradiance
Dear Josh, To maintan the output dc voltage constant with resistive load you have to required PI controller. with resistive l...

2年弱 前 | 0

回答済み
TMS320F28335: Simulink generates code automatically
Dear Min, For This, You have to required Two sumulation model, first one is control model and second one is host model. For ...

2年弱 前 | 0

回答済み
TMS320F28335: Simulink generates code automatically
Dear Big Min, For DSP kit(TMC320F28335) interfacinng with matlab, You need to do following steps:- Go to the add on and add...

2年弱 前 | 0

| 採用済み

質問


Implementation of real time close loop control on TMS320F28379D dsp controller using MATLAB Simulation
Hi, I am working on implementation of real time close loop control on dsp TMS320F28379D, for synchronization of voltage source...

2年弱 前 | 0 件の回答 | 0

0

回答

回答済み
I AM NOT ABLE TO INTERFACE TMS320F28379D
Dear Aratrika, For DSP kit(TMC320F28379D) interfacinng with matlab 12018a. You need to do following steps:- Go to the add on...

約2年 前 | 0

| 採用済み

もっと読み込む