introduce dead band time for a complementary signal in TI processor

Hi,
could anyone tell me how to introduce dead band time for 10us in TI DSP processor using simulink?
I tried with period of 1000 but it is not working.

1 件のコメント

Ramana manohar
Ramana manohar 2022 年 1 月 27 日
Required dead band is calculated based on the system clock frequecy. Please reffer to the TI doc associated to the ePWM module.
For example for f28335(https://mil.ufl.edu/3744/docs/TI_DSP/TI-docs/sprug04a.pdf), I have claculated the dead band as shown below:
Required dead band = 50n sec
Sysrem clock =100M Hz
dead Band = 50n*100M = 5
FED = DBFED × TTBCLK
RED = DBRED × TTBCLK
Where TTBCLK is the period of TBCLK, the prescaled version of SYSCLKOUT
TBCLK = SYSCLKOUT

サインインしてコメントする。

回答 (1 件)

Dr. Pemendra Kumar Pardhi
Dr. Pemendra Kumar Pardhi 2022 年 1 月 26 日

0 投票

Hello venkata Kumar, Can you share your Epwm A and Epwm B screenshot. I thik you are obtained just inverted Signal fron EPWM A and EPWM B.

コミュニティ

カテゴリ

質問済み:

2022 年 1 月 26 日

コメント済み:

2022 年 1 月 27 日

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by