Unexpected noise in output voltage for buck converter

Hello! I'm trying to simulate the buck converter using statespace equations. I don't understand why the output voltage has a ripple in the second photo (uncompensated system) and then, in the first one there is no ripple (compensated system)

2 件のコメント

madhan ravi
madhan ravi 2021 年 7 月 4 日
編集済み: madhan ravi 2021 年 7 月 4 日
See the y axis scale of each picture.
Vasilica Cioban
Vasilica Cioban 2021 年 7 月 4 日
編集済み: Vasilica Cioban 2021 年 7 月 4 日
no, this isnt the problem. i tried to zoom in the both of them and the first one is just a line without any ripple

サインインしてコメントする。

回答 (1 件)

Pat Gipper
Pat Gipper 2021 年 7 月 6 日

0 投票

The Puse Generator has a period of 1/100000 seconds, which is injecting 100 KHz pulses into your system. The ripple is simply the response to those pulse. Try setting Period=10 and Amplitude=24 and you will get rid of the ripple.