how to put input value for FEM-Parameterized Linear Actuator (.1)Flux partial derivative wrt current, dPhi(i,x)/di (unit is web/A )2)Flux partial derivative wrt displacement)
MATLAB provides lots of ways for you to determine partial derivatives from the flux. One way, for example, is to fit a polynomia...

15日 前 | 0

| 採用済み

回答済み
Check Thyristor Holding Current in Simscape model
The holding current will depend on the NPN and PNP transistor I-V characteristics which, in-turn, depend on forward gain, forwar...

8ヶ月 前 | 1

| 採用済み

回答済み
How to generate the proper PWM Signal to control the Simscape RC Servo Block
An RC Servo contains its own controller that sets the output angle. The angle set set by the pulse period of the voltage applied...

約2年 前 | 0

| 採用済み

回答済み
Reconstruct SIC MOSFET switching losses out of datasheet - simscape model has a big deviation
Hi Florian Root cause of your difficulties here is that the datasheet does not give you everything you need to accurately predi...

2年以上 前 | 1

| 採用済み

回答済み
Add dead time in Simulink
We now have the Gate Driver and Half-Bridge Drive blocks in Simscape™ Electrical™ which allow you to specify dead-time/blanking ...

2年以上 前 | 1

| 採用済み

回答済み
Solver for common mode noise
For Simscape models, you should in general choose an implicit solver e.g. ode23t, ode15s or daessc. However, results should be c...

約3年 前 | 0