Solver for common mode noise
15 ビュー (過去 30 日間)
古いコメントを表示
hi
i have a three phase inverter simulation based on SPICE models.I am trying to obtain the common-mode noise level of this inverter using Spectrum Analyzer in simulation.I want to know your suggestions about choosing the right solver (Also state the reason for your suggest).
0 件のコメント
採用された回答
Rick Hyde
2021 年 1 月 4 日
For Simscape models, you should in general choose an implicit solver e.g. ode23t, ode15s or daessc. However, results should be comparable for all solvers provided that you pick abstol and reltol values that reflect the accuracy you need. It is best practice not to use the "auto" abstol option; better to take control and set the value that you need. Ensuring the max step size is not too large can also help simulation speed by reducing the number of solver resets.
Please see this example which may help with setting up your model:
Regards
Rick Hyde
0 件のコメント
その他の回答 (0 件)
コミュニティ
その他の回答 パワー エレクトロニクス コミュニティ
参考
カテゴリ
Help Center および File Exchange で Switches and Breakers についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!