how to sampling the signal in order to match the two signal?

2 ビュー (過去 30 日間)
Keshasni Earichappan
Keshasni Earichappan 2021 年 8 月 14 日
回答済み: Star Strider 2021 年 8 月 15 日
Hi.i am having trouble to set both data (mc & torque) on the same time axis.MC-voltage signal need to sampled at 5 kHz and low-pass filtered with a cutoff frequency 10 Hz in order to match with the torque(maybe).Basically,I need to match the two different time series into one same time series.Hope anyone can help me to figure it out.Thanks in advance
  1 件のコメント
dpb
dpb 2021 年 8 月 14 日
Look at resample in Signal Processing Toolbox...

サインインしてコメントする。

採用された回答

Star Strider
Star Strider 2021 年 8 月 15 日
The first 2 column in ‘TORQUE’ are missing, so they are removed here.
% C1 = readcell('https://www.mathworks.com/matlabcentral/answers/uploaded_files/711992/TORQUE.txt')
% nrmissing = [nnz(ismissing([C1{:,1}])) nnz(ismissing([C1{:,2}])) size(C1,1)]
T1 = readtable('https://www.mathworks.com/matlabcentral/answers/uploaded_files/711992/TORQUE.txt', 'VariableNamingRule','preserve');
T1 = removevars(T1,{'Var1','Var2'})
T1 = 7967×2 table
TIME TORQUE ____ ______ 0 0 10 0.7 20 1.1 30 6.5 40 6.5 50 6.4 60 6.5 70 6.4 80 6.1 90 6.1 100 6.4 110 7.1 120 7.9 130 8.3 140 7.9 150 8
T2 = readtable('https://www.mathworks.com/matlabcentral/answers/uploaded_files/712562/MC.txt', 'VariableNamingRule','preserve')
T2 = 90483×2 table
Time MC[v] ________ ______ 0 1.8297 0.000999 1.8289 0.001998 1.8297 0.002997 1.8297 0.003996 1.8305 0.004996 1.8289 0.005996 1.8297 0.006997 1.8313 0.007996 1.8305 0.008995 1.8281 0.009994 1.8297 0.010995 1.8305 0.011994 1.8305 0.012995 1.8297 0.013994 1.8297 0.014993 1.8305
Fs = 100; % Resample To 100 Hz Sampling Frequency
[TORQUEr,T_TIMEr] = resample(T1.TORQUE, T1.TIME, Fs);
[MCvr,V_TIMEr] = resample(T2.('MC[v]')-mean(T2.('MC[v]')), T2.Time, Fs);
MCvr = MCvr + mean(T2.('MC[v]'));
figure
subplot(2,1,1)
plot(T_TIMEr, TORQUEr)
grid
xlabel('t')
ylabel('Torque (Resampled)')
subplot(2,1,2)
plot(V_TIMEr, MCvr)
xlabel('t')
ylabel('MC[v] (Resampled)')
grid
They both have the same 100 Hz sampling frequencies, however they retain significantly different time vectors.
.

その他の回答 (1 件)

Sulaymon Eshkabilov
Sulaymon Eshkabilov 2021 年 8 月 14 日
% They perfectly match as you can see the plot below.
MC = readtable('https://www.mathworks.com/matlabcentral/answers/uploaded_files/711992/MC.txt');
Torque = readtable('https://www.mathworks.com/matlabcentral/answers/uploaded_files/711992/TORQUE.txt');
plot(MC.TIME, MC.TORQUE, 'bx', Torque.TIME, Torque.TORQUE, 'r'), legend('MC','Torque')
% If you need to resample them then, apply resample()
% See here: https://www.mathworks.com/help/signal/ref/resample.html
  3 件のコメント
Sulaymon Eshkabilov
Sulaymon Eshkabilov 2021 年 8 月 15 日
Yes, it might be. I've written the code on online here and executed it, rightaway. I have not used a desktop matlab since my matlab license was not activated.
Keshasni Earichappan
Keshasni Earichappan 2021 年 8 月 15 日
hi @Scott MacKenzie & @Sulaymon Eshkabilov....sorry i had attached the wrong MC.txt file jn..here i have attached the updated one..I need to match the two different time series into one same time series(sampling period).Is it possible? :)