4 way 2 position directional control valve in simscape fluid

2 ビュー (過去 30 日間)
murali manohar boopathy
murali manohar boopathy 2021 年 4 月 24 日
I am not able to get a 4 way 2 position dcv in my simscape library instead there are only 4 way 3 position valve configurations, in the simscape , how to add 4 way 2 position valves and its configurations into my library?

回答 (2 件)

Jocie Kluger
Jocie Kluger 2021 年 4 月 26 日
Hi Murali,
The 4-Way 2-Position valve was introduced to the Isothermal Liquid library in R2021a. For other domains and releases, it is possible to simulate many 4-Way 2-Position valves using the 4-Way 3-Position library blocks. For aesthetic purposes, you could put a mask over the block so show a picture of a 4-Way 2-Position block.
Hope this helps,
Jocie

Yifeng Tang
Yifeng Tang 2021 年 4 月 26 日
There are multiple physical domains that have 4-way valve blocks, so it's not clear from your question which specific domain/block you were looking at. I'll try to answer as much as I can.
For the isothermal liquid (IL) domain, there is a 4-way, 2-position directional valve.
For thermal liquid (TL), Hydraulics, and Gas domains, the 4-way valves all appear to be 4-way, 3 position valves. However, if you have a "zero-lapped" parametrization for your opening vector, you basically get a 4-way, 2 position valve, because spool range for the neutral position shrinks to zero. It's best explained in the "Orifice Opening" section of the Documentation page on the 4-way valve in the Hydraulics domain: https://www.mathworks.com/help/releases/R2021a/physmod/hydro/ref/4waydirectionalvalve.html#bvnvqp8-1
Hope this helps.

カテゴリ

Help Center および File ExchangeUpgrading Hydraulic Models to Use Isothermal Liquid Blocks についてさらに検索

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by