Simulink Real-Time CPU overload in standalone mode

10 ビュー (過去 30 日間)
Alex Austin
Alex Austin 2019 年 4 月 12 日
コメント済み: Alex Austin 2020 年 9 月 4 日
Hi,
Using 2017B and a Speedgoat Mobile Real Time Target machine we are seeing CPU overload errors when built and run in standlone mode, but exactly the same model built and run in normal (DOS loader) mode runs fine with no overloads. The model is an automotive controller using CAN and UDP connectivity (no phyiscial I/O).
Anyone got any ideas where to investigate more to understand this problem?
Thanks.
  3 件のコメント
Wenjie Chen
Wenjie Chen 2020 年 8 月 21 日
I have encouter the same issue. Got any solution already?
Alex Austin
Alex Austin 2020 年 8 月 24 日
Sorry no - recently tried same experiment on R2020a version and same result.
I've basically given up on the standalone mode - I just think that not many people use it, and consequently they don't really maintain or develop it as well as they could.

サインインしてコメントする。

回答 (1 件)

Ivo Houtzager
Ivo Houtzager 2020 年 9 月 1 日
I had the same issue. For me disabling "USB Support" in the target settings solved it.
Also the disable SMI block from https://de.mathworks.com/matlabcentral/fileexchange/18832-disabling-smis-on-intel-r-ich5-chipsets works well if you have a supported chipset.
  1 件のコメント
Alex Austin
Alex Austin 2020 年 9 月 4 日
Thanks for the ideas - I'll give them a go and let you know if it works

サインインしてコメントする。

カテゴリ

Help Center および File ExchangeTarget Computer Setup についてさらに検索

製品


リリース

R2017b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by