HDL coder Generated Model and Simulink Model Results Does not Match

Hallo
So i have my model, where 44.1 kHz signal comes in and the output is 11.28 MHz. I am using FIR interpolation filter for up sampling the input signal. I use HDL coder to generate the VHDL code and download the design to a FPGA, i am using 22.56 MHz as my FPGA system clock. But at the output i get some corrupted results and it looks like my output has a Fs of 22.56 MHz.
I am using pipelines in my filter design to increase the timing constraints. And when i compare the generated model results with my simulation results, i can see some error. For example at some points when my simulink simulation result is 1, the generated model result goes to 0 and vice versa. Any idea why this is happening?
What could be the solution, or any test to identify the problem

回答 (2 件)

Bharath Venkataraman
Bharath Venkataraman 2017 年 5 月 22 日

0 投票

You may be seeing the 0s inserted by the pipeline registers in the output.
One way to debug is to have a parallel valid in - valid out signal chain to the FIR Interpolator. The appropriate delays will be added to this valid signal and you should look at the value only when valid is high.

1 件のコメント

shauk
shauk 2017 年 5 月 23 日
Hallo thanks for the answer, but could you please explain the line in bit details, or suggest me a documentation where i could find some explanation. "You may be seeing the 0s inserted by the pipeline registers in the output."

サインインしてコメントする。

shauk
shauk 2017 年 5 月 23 日

0 投票

Hallo thanks for the answer, but could you please explain the line in bit details, or suggest me a documentation where i could find some explanation. "You may be seeing the 0s inserted by the pipeline registers in the output."