Errors in feedback control after setting the input of a prismatic joint to motion/provided by input
2 ビュー (過去 30 日間)
古いコメントを表示
Hello, I am currently controlling the prismatic joint actuators of a Stewart platform using Simulink. I have set the input to motion/provided by input in order to change the position of the eight actuators over time. However, when I try to perform feedback control in the simulation, I encounter errors as shown in the image below. Feedback control works when the input is set to force, but why do these errors occur when the input is set to motion? If anyone knows the answer, I would be very grateful for your help.
0 件のコメント
採用された回答
Divyanshu
2024 年 8 月 6 日
A possible reason for such errors is that an algebraic loop is formed in your model when input is set to motion.
For more information about identification and removal of algebraic loops have can refer the following links:
Hope it helps!
2 件のコメント
Yifeng Tang
2024 年 8 月 7 日
Unit Delay may work just fine, or create some numerical inefficiency, depending on the nature of the rest of your system. You may check the step sizes and solver resets using Solver Profiler and see if that's the case. One potential concern is mixing discrete block (Unit Delay) with continuous ones (Simscape). If indeed that gives you issues, consider replace the Unit Delay with a Transfer Fcn block, with a reasonable time constant.
その他の回答 (0 件)
参考
カテゴリ
Help Center および File Exchange で Assembly についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!