HDL FIFO Reset Problem
1 回表示 (過去 30 日間)
古いコメントを表示
Hi,
I'm working with HDL FIFO Classic Module and I've discovered that when I do a reset (to local reset port) , FIFO Number of register entries turns to 1 and the empty signal turns to low level. Are there anything wrong with Classic HDL FIFO module or am I missing something?
NOTE: And HDL code generated does just the descrived above
fifo_sample_count_next <= to_unsigned(16#0001#, 16) WHEN rst /= '0' ELSE
fifo_sample_count + to_unsigned(16#0001#, 16) WHEN (fifo_write_enable AND ( NOT fifo_read_enable)) = '1' ELSE
fifo_sample_count + to_unsigned(16#FFFF#, 16) WHEN (( NOT fifo_write_enable) AND fifo_read_enable) = '1' ELSE
fifo_sample_count;
0 件のコメント
回答 (1 件)
Kiran Kintali
2023 年 12 月 1 日
Would you be able to share your sample model? You can prune it to just show HDL FIFO block.
Found a relevant report here. Need to investigate further if the issue is identical.
An update patch is planned for this bug.
6 件のコメント
Kiran Kintali
2023 年 12 月 6 日
The issue is resolved in the latest releases of MATLAB and HDL Coder and is being backported to previous releases. https://www.mathworks.com/support/bugreports/2982578