フィルターのクリア

HDL IP Core generation for Xilinx Vivado fails since the year turned from 2021 to 2022

51 ビュー (過去 30 日間)
Since returning to the office in 2022, I have been unable to use HDL Workflow Advisor with Xilinx Vivado. I see the following error message in HDL Workflow Advisor in Task 3.2:
Failed Task "Vivado IP Packager" unsuccessful. See log for details. Generated logfile: hdl_prj\hdlsrc\modelname\workflow_task_VivadoIPPackager.log
Error using hdlturnkey.ip.IPEmitterVivado/packageVivadoIP
Task "Vivado IP Packager" unsuccessful. See log for details.
Generated logfile: hdl_prj\hdlsrc\modelname\workflow_task_VivadoIPPackager.log
Error in hdlturnkey.ip.IPEmitterVivado/generateIPCore
Error in hdlturnkey.ip.IPDriver/generateIPCore
Error in hdlturnkey.TurnkeyDriver/makehdlturnkeycore
Error in hdlturnkey.TurnkeyDriver/makehdlturnkey
Error in slhdlcoder.HDLCoder/makehdlturnkey
Error in downstream.DownstreamIntegrationDriver/runIPCoreCodeGen
Error in generateIPCore
Error in Simulink.ModelAdvisor/executeCheckCallbackFct
Error in Simulink.ModelAdvisor/run
Error in Simulink.ModelAdvisor/runCheck
Error in ModelAdvisor.Node/runTaskAdvisor
Error in ModelAdvisor.Node.run
If I check the log at \hdl_prj\hdlsrc\modelname\workflow_task_VivadoIPPackager.log, I see the following error message:
"bad lexical cast: source type value could not be interpreted as target while executing"
Task "Vivado IP Packager" unsuccessful. See log for details.
Generated logfile:
****** Vivado v2018.3 (64-bit)
**** SW Build 2405991 on Thu Dec 6 23:38:27 MST 2018
**** IP Build 2404404 on Fri Dec 7 01:43:56 MST 2018
** Copyright 1986-2018 Xilinx, Inc. All Rights Reserved.
source vivado_ip_package.tcl -notrace
INFO: [IP_Flow 19-234] Refreshing IP repositories
INFO: [IP_Flow 19-1700] Loaded user IP repository 'c:/Users/Li/Desktop/Mankov/hdl_prj/ipcore'.
WARNING: [IP_Flow 19-3656] If you move the project, the path for repository 'c:/Users/Li/Desktop/Mankov/hdl_prj/ipcore' may become invalid. A better location for the repository would be in a path adjacent to the project. (Current project location is 'c:/Users/Li/Desktop/Mankov/hdl_prj/ipcore/DUT_IO33x_IP_v1_0/prj_ip'.)
INFO: [IP_Flow 19-2313] Loaded Vivado IP repository 'C:/Xilinx/Vivado/2018.3/data/ip'.
INFO: [IP_Flow 19-5107] Inferred bus interface 'DMA_Stream_FPGA_to_CPU_Master' of definition 'xilinx.com:interface:axis:1.0' (from Xilinx Repository).
INFO: [IP_Flow 19-5107] Inferred bus interface 'AXI4_Lite' of definition 'xilinx.com:interface:aximm:1.0' (from Xilinx Repository).
INFO: [IP_Flow 19-5107] Inferred bus interface 'AXI4_Lite_ARESETN' of definition 'xilinx.com:signal:reset:1.0' (from Xilinx Repository).
INFO: [IP_Flow 19-5107] Inferred bus interface 'IPCORE_RESETN' of definition 'xilinx.com:signal:reset:1.0' (from Xilinx Repository).
INFO: [IP_Flow 19-5107] Inferred bus interface 'AXI4_Lite_ACLK' of definition 'xilinx.com:signal:clock:1.0' (from Xilinx Repository).
INFO: [IP_Flow 19-5107] Inferred bus interface 'IPCORE_CLK' of definition 'xilinx.com:signal:clock:1.0' (from Xilinx Repository).
INFO: [IP_Flow 19-4728] Bus Interface 'AXI4_Lite_ARESETN': Added interface parameter 'POLARITY' with value 'ACTIVE_LOW'.
INFO: [IP_Flow 19-4728] Bus Interface 'IPCORE_RESETN': Added interface parameter 'POLARITY' with value 'ACTIVE_LOW'.
INFO: [IP_Flow 19-4728] Bus Interface 'AXI4_Lite_ACLK': Added interface parameter 'ASSOCIATED_BUSIF' with value 'AXI4_Lite'.
INFO: [IP_Flow 19-4728] Bus Interface 'AXI4_Lite_ACLK': Added interface parameter 'ASSOCIATED_RESET' with value 'AXI4_Lite_ARESETN'.
INFO: [IP_Flow 19-4728] Bus Interface 'IPCORE_CLK': Added interface parameter 'ASSOCIATED_RESET' with value 'IPCORE_RESETN'.
WARNING: [IP_Flow 19-3158] Bus Interface 'DMA_Stream_FPGA_to_CPU_Master': FREQ_HZ bus parameter missing from AXI interface when interface is not associated to a clock.
WARNING: [IP_Flow 19-3153] Bus Interface 'IPCORE_CLK': ASSOCIATED_BUSIF bus parameter is missing.
INFO: [IP_Flow 19-2181] Payment Required is not set for this core.
INFO: [IP_Flow 19-2187] The Product Guide file is missing.
bad lexical cast: source type value could not be interpreted as target
while executing"rdi::set_property core_revision 2201031458 {component component_1}"
invoked from within
"set_property core_revision 2201031458 [ipx::current_core]"
(file "vivado_ip_package.tcl" line 57)
INFO: [Common 17-206] Exiting Vivado at Mon Jan 3 14:58:23 2022...
Elapsed time is 12.568 seconds.

採用された回答

MathWorks HDL Coder Team
MathWorks HDL Coder Team 2022 年 1 月 4 日
編集済み: Stefanie Schwarz 2022 年 1 月 10 日
Refer to the following External Bug Report for a resolution to this issue:
Note: You will need to login to your MathWorks account to access this link.
  6 件のコメント
Yaddehi De Silva
Yaddehi De Silva 2022 年 1 月 19 日
Took me 2 weeks to find this solution and it works
Yongjie
Yongjie 2023 年 11 月 10 日
Where can I find a patch for Matlab2022b please?

サインインしてコメントする。

その他の回答 (1 件)

Kiran Kintali
Kiran Kintali 2022 年 1 月 19 日
編集済み: Kiran Kintali 2022 年 1 月 19 日
Posting this again here for more visibility into this issue and proposed fix for HDL Coder Xilinx IP Core Workflow.
To fix the issue with HDL Coder please apply the patch in the above link.
  3 件のコメント
Kiran Kintali
Kiran Kintali 2022 年 4 月 27 日
Yes, the patch does not exist for 15b. See fix releases here.
Please contact MathWorks technical support for guidance on 15b release.
Yongjie
Yongjie 2023 年 11 月 10 日
Where can I find a patch for Matlab2022b please?

サインインしてコメントする。

製品

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by