Main Content

Check for disabled and parameterized library links

Check ID: mathworks.hism.hisl_0075

Description

Identifies the disabled and parameterized library links in the model.

Available with Simulink® Check™.

Results and Recommended Actions

ConditionRecommended Action
One or more blocks in the model are parameterized library links.

Use one of the following options to resolve the issue by right-clicking on the violated block and selecting an appropriate option from the Library Link menu:

  • Click Push Link to propagate the changes to the library.

  • Click Select Restore Link to discard the changes.

One or more blocks in the model are disabled library links.

Resolve the link using these steps:

  1. Right-click the violated block in the Simulink diagram.

  2. From the Library Link menu, select Restore Link.

Capabilities and Limitations

  • Runs on library models.

  • Analyzes content in masked subsystems. By default, the input parameter Look under masks is set to all.

  • Analyzes content of library-linked blocks. By default, the input parameter Follow links is set to on.

  • Allows exclusions of blocks and charts.

See Also