photo

ashish ahir


cybage

2015 年からアクティブ

Followers: 0   Following: 0

統計

All
  • First Submission
  • Knowledgeable Level 2
  • First Answer

バッジを表示

Feeds

表示方法

回答済み
Invalid MEX-file '\\Client\C$\Users\epappaia\Documents\Speranza\yprime.mexw64': Access is denied.
you can try this: Could your MEX-File require another .DLL, and it is that DLL that cannot be found? Use a tool like Dependency...

8年以上 前 | 0

| 採用済み

質問


clock speed requirement not getting
i have used f28335 pocessor, which has 150MHz clock speed. i need atleast 200MHz clock speed. Can anyone suggest same processors...

8年以上 前 | 1 件の回答 | 0

1

回答

回答済み
How to avoid C2802x COMP simulink module output as single(float) format?
can you upload screenshot of this setting parameters?

9年弱 前 | 0

回答済み
How to control LEDs and read switches from Zynq using Simulink?
May be this video can help you. http://in.mathworks.com/hardware-support/zynq.html

9年弱 前 | 0

回答済み
Can i attach physical system with this model
not able to view model clearly, which you have uploaded. Upload neatly.

9年弱 前 | 0

| 採用済み

回答済み
Where do I change the path for Embedded Coder compiler
have you tried xmakefilesetup? are you working on any specific target?

9年弱 前 | 0

| 採用済み

回答済み
Simulink - problem with generation of time depends signal
Marcin, use counter inside triggered subsystem. triggered subsystem will be triggered when your variable will have assumed valu...

9年弱 前 | 0

質問


problem with control using PID controller
I am using simulink and TI F28335 to implement close loop control logic via PID control. Inverter output voltage drops by 4V wh...

約9年 前 | 0 件の回答 | 0

0

回答

質問


Control algorithm stops working after 5 min 30 sec on F28335.
I want to generate A sin(Wt) with A and W as external signals. As shown in figure i have done that. Sample time for blocks is 50...

約9年 前 | 0 件の回答 | 0

0

回答

質問


problem with automatic stoping of controller
i implemented inverter control algorithm using simulink on F28335 using target specific blocks. auto generated code working fine...

約9年 前 | 0 件の回答 | 0

0

回答

質問


problem with automatic stoping of controller
i implemented inverter control algorithm using simulink on F28335 using target specific blocks. auto generated code working fine...

約9年 前 | 0 件の回答 | 0

0

回答

質問


Difficulty in getting inverter transfer function
Hi, i want to design an inverter with controllable output AC voltage. To check PID controller action i require full bridge inver...

9年以上 前 | 3 件の回答 | 0

3

回答

質問


difficulty with PID controller usage and CCSv6 PIL testing
I am using CCSV6 with simulink and F28335.I want to make full bridge inverter.i simulated control algorithm using continuous PID...

9年以上 前 | 1 件の回答 | 0

1

回答

質問


F28335 ePWM block duty cycle logic for SPWM wave
I want to generate SPWM wave with 20KHz switching frequency and 50Hz modulating signal frequency. I am using F28335 ePWM block i...

9年以上 前 | 1 件の回答 | 0

1

回答

質問


why there is delay between 2 ePWM signal on f28335 C2000 controller using embedded coder generated code?
I am using F28335 Delfino to generate ePWm outputs. I want 4 same PWM output signals. I have configured same parameters in simul...

9年以上 前 | 0 件の回答 | 0

0

回答

回答済み
[DISCONTINUED] MATLAB Answers Wish-list #2 (and bug reports)
i wish matlab answer forum was quick and responsive as TI e2e community.

9年以上 前 | 0

回答済み
What is missing from MATLAB?
A quick reply mechanism in matlab answer forum.

9年以上 前 | 0

回答済み
[DEPRECATED] What frustrates you about MATLAB?
As i am a beginner, i have lots of doubts. I used to post these doubts on matlab answers forum. I exprerienced that, i am not ge...

9年以上 前 | 0

質問


implementing inverter controller profile model taking buck converter as reference
<http://in.mathworks.com/help/supportpkg/texasinstrumentsc2000/examples/dc-dc-buck-converter.html Buck converter> i want to...

9年以上 前 | 0 件の回答 | 0

0

回答

質問


having trouble in understanding buck converter
<http://in.mathworks.com/help/supportpkg/texasinstrumentsc2000/examples/dc-dc-buck-converter.html Buck converter> why data lo...

9年以上 前 | 0 件の回答 | 0

0

回答

質問


visualize C2000 PWM pulses on simulink
<http://in.mathworks.com/help/supportpkg/texasinstrumentsc2000/ug/c280xc2802xc2803xc2805xc2806xc28x3xc2834xf28m3xepwm.html ePWM>...

9年以上 前 | 0 件の回答 | 0

0

回答

質問


visualize c2000 pwm pulses without actual hardware
<http://in.mathworks.com/help/supportpkg/texasinstrumentsc2000/examples/dc-dc-buck-converter.html buck converter> i dont have...

9年以上 前 | 0 件の回答 | 0

0

回答

質問


PID control action for AC reference of variable amplitude and frequency.
i have seen example of controlling output dc voltage of DC to DC buck converter using PID controller. I want to implement DC to ...

9年以上 前 | 1 件の回答 | 0

1

回答

質問


PID working with sine wave as reference
i have seen example of controlling output dc voltage of DC to DC buck converter using PID controller. I want to implement DC to ...

9年以上 前 | 1 件の回答 | 0

1

回答

質問


verify code without hardware
i am using f28335 delfino control card for building inverter. i have implemented control algorithm for the same and simulated us...

9年以上 前 | 0 件の回答 | 0

0

回答

質問


matlab r2013a and ccsv6
I have MATLAB R2013a and CCS 6.0.1. I am trying to use to create project using c2000 library. I am using TMS320F28335 Experiment...

9年以上 前 | 1 件の回答 | 0

1

回答

回答済み
i am using CCSV5.4 with MATLAB2012b but MATLAB simulink model is not build and i check on commond window checkEnsetup('ccsv5',;f28335','check') so find on commond window is this any one guide me how to solve my problem?
same problem. I typed ccsv4 but still every field are coming blank. Tried adding environment variable also. But still problem...

9年以上 前 | 0

質問


problem in setting CCSv6 with MATLAB R2013a
I have MATLAB R2013a and CCS 6.0.1. I am trying to use to create project using c2000 library. I am using TMS320F28335 Experime...

9年以上 前 | 0 件の回答 | 0

0

回答

質問


how to Utilize HRPWM output pins of TMS320F28335 in SImulink generated code?
TMS320F28335 has 6 HRPWM outputs. Simulink model containing pulse generator block generates code. I want that code to use HRPWM...

9年以上 前 | 0 件の回答 | 0

0

回答

送信済み


PWM generation without any other source
PWM with adjustable freqency and duty cycle.

9年以上 前 | ダウンロード 3 件 |

さらに読み込む