Ke
Followers: 0 Following: 0
Feeds
質問
I want to customize a 34cc vapor injection compressor model in Simscape. How do I go about it? How can I simulate the vapor injection process and the intermediate compression
Hello,I want to customize a 34cc vapor injection compressor model in Simscape to simulate and compare the performance of a vapor...
7日 前 | 0 件の回答 | 0
0
回答質問
Two-phase flow control valve
Hello, is there a two-phase flow regulator in Simscape that does not change the pressure on both sides?
6ヶ月 前 | 1 件の回答 | 0
1
回答質問
The particle swarm optimization algorithm optimizes the scale factor and quantization factor of the fuzzy PID controller
I want to use the particle swarm optimization algorithm to optimize the scale factor and quantization factor of the fuzzy PID co...
9ヶ月 前 | 1 件の回答 | 0
1
回答質問
The element 1 in SCDPotentialLinearizationIOs structure is not referring to an existing block in the model。
Hello,I don't know where to operate when adjusting the PI control of the model, and suddenly the following error appears: The el...
10ヶ月 前 | 1 件の回答 | 0
1
回答回答済み
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
Hello,I don't seem to have tried the peak you mentioned, I'm not sure what conditions are suitable for him, I adjusted his param...
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
Hello,I don't seem to have tried the peak you mentioned, I'm not sure what conditions are suitable for him, I adjusted his param...
10ヶ月 前 | 0
回答済み
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
I don't have his differential equations here, I'm using the compressor components in Simscape and using Simluink to control the ...
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
I don't have his differential equations here, I'm using the compressor components in Simscape and using Simluink to control the ...
10ヶ月 前 | 0
回答済み
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
I haven't tried this before, I'm a direct control of the actuator, but I feel that this phenomenon seems a little strange. It's ...
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
I haven't tried this before, I'm a direct control of the actuator, but I feel that this phenomenon seems a little strange. It's ...
10ヶ月 前 | 0
回答済み
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
Hello, I found that the model you built does not seem to initialize the PID parameters, and directly input the output of the fuz...
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
Hello, I found that the model you built does not seem to initialize the PID parameters, and directly input the output of the fuz...
10ヶ月 前 | 0
質問
Fuzzy control problem:(1)input 2 expects a value in range [-1.5 1.5], but has a value of 4.36559e+24;
In 'EV_Thermal_Management_wendukongzhi_zhileng/Controls/Compressor Control/ÿÿÿÿ/Fuzzy Logic Controller', input 2 expects a val...
10ヶ月 前 | 2 件の回答 | 0
2
回答質問
I want to use a solenoid valve to achieve two-phase flow on/off
Hello,I want to use a solenoid valve to achieve two-phase flow on/off, I tried to use the Orifice (2P) module, but its cross-flo...
1年以上 前 | 1 件の回答 | 0
1
回答質問
2P-2P Heat Exchanger
I am trying to build a two-phase flow heat exchanger (2P-2P), which means that the heat exchanger on both sides of the heat exch...
1年以上 前 | 1 件の回答 | 0
1
回答質問
two-phase flow 4-way valve
I want to build a two-phase flow 4-way valve using Simscape, what do I do?
1年以上 前 | 1 件の回答 | 0
1
回答質問
Why is my electronic expansion valve not working
Hello, I am building a model of a heat pump air conditionerI am trying to use an electronic expansion valve for throttling, but ...
1年以上 前 | 0 件の回答 | 0
0
回答質問
Simscape how to set up a multi-process evaporator or condenser
Hello, I want to create a parallel flow microchannel condenser with four processes but there doesn't seem to be a similar module...
1年以上 前 | 1 件の回答 | 0
1
回答質問
Custom quasi-secondary compressor models report errors
I want to add a make-up port to the controllable mass flow element, but when I run it he gets the error: Cannot find parameter '...
1年以上 前 | 1 件の回答 | 0
1
回答質問
Heat Pump Air Conditioner
I'm trying to build a make-up enthalpy heat pump air conditioner with Simscape but I don't know how to start, does anyone know h...
1年以上 前 | 1 件の回答 | 0