Equivalent of #define's for matlab coder?
Hi, It can be implemented by using custom storage class "ImportedExtern". Hence EC will generate the variable with extern stora...

1年以上 前 | 0

回答済み
The 'duration' operator cannot be bound to more than one state
There can be many solutions, one would be placing both a and b into a single parent state the let the parent state exit to State...

1年以上 前 | 0

回答済み
How to set "Show Name" of Simulink block to "Auto" using Matlab script?
Please set the parameter "Hide Automatic Name" to "on" that sets "ShowName" of the block to "Auto"

1年以上 前 | 1

| 採用済み

回答済み
How to find out whether a stateflow input variable receives an explicit value = 0 or is unconnected? How to treat optional inputs?
Hi, It can be done by creating a mask, sample model is here. Hope it helps. Thanks

約2年 前 | 0

送信済み


Handle unconnected input Using Mask
To detect and handle an unconnected input for a library block

約2年 前 | ダウンロード 1 件 |

Thumbnail

回答済み
How to programmatically create argin and argout ports in simulink function
Hi, Arg In and Arg Out blocks will not be present in simulink library browser. Hence add_block cannot refer to the this block f...

約2年 前 | 0

| 採用済み

回答済み
How can I introduce a block created in Simulink into the Simulink Library Browser?
Hi, Please refer to this video. Hope it helps. Thanks.

約2年 前 | 0

回答済み
Arrays have incompatible sizes for this operation.
Hi, In the calculation for the highlighted section please index (i,2) Thanks, Muthukumar

約2年 前 | 0

回答済み
Repeated sequence with enumerated data
Hi, Please convert the array into double using following command in the output values section of the block. double(<EnumName>....

2年以上 前 | 0

回答済み
In Simulink, when a condition is met, I want to keep a constant result even when this condition ends.
Hi, Please refer to the attachment. Hope you are referring to this logic. Thanks Static Temp=0; if (u1>u2 && Temp !=1) Temp...

2年以上 前 | 0

回答済み
In simulink, debouncing
Hi, Using stateflow, you can implement this with after function whereas using simulink counter logic has to be implemented. Pl...

2年以上 前 | 0

回答済み
How can I implement a custom datatype in Simulink model So, that the generated code is same as Union datatype in C.
Hi, Please find one of the workaround here. Thanks.

2年以上 前 | 0

回答済み
union structure in simulink
Hi, Please refer to this sample model. Hope this helps. Thanks.

2年以上 前 | 0

回答済み
C Union data type in Matlab/Simulink
Hi, One of the workaround is here. Thanks

2年以上 前 | 0

送信済み


Use Union Datatype in Simulink
Simulink doesn't generate Union datatype but the same can be imported into Simulink

2年以上 前 | ダウンロード 10 件 |

回答済み
Use pointers in simulink
Hi, You can perform this using following method. Create a Simulink function with input and output arguments Right click the b...

2年以上 前 | 0

送信済み


Using Pointer in Simulink function
Model explains how to use a pointer arguments in a C/C++ generated code from Simulink function

2年以上 前 | ダウンロード 3 件 |

Thumbnail

回答済み
Regarding bit generator
Hi, Please use "Serializer1D" block which is introduced in R2014b. Configure the parameter "Ratio" and Idle Cycles From your ...

2年以上 前 | 0

回答済み
How to setup Simulink logs out .mat format?
Hi, In the newer versions of matlab by default, Simulink creates .mat file with version 7.3 You can add these commands in Mode...

2年以上 前 | 0

回答済み
stateflow interpretation blocks- integrator
Hi, These are Causal Discrete systems. Let's assume input is x and output is y. Hope you are good at C. Case 1: Accumulates x...

2年以上 前 | 0

回答済み
set configuration of State flow using M script
Hi, Please use the following commands to modify it and also make sure the model is not in simulation mode. Hope this helps. Th...

2年以上 前 | 0

回答済み
State transition which needs to be triggered when a condition is met for a fixed period of time.
Hi, Based on your implementation, adding a self transition with condition Input != 1, Please refer to the screenshot. Thanks.

2年以上 前 | 0

回答済み
Can I force Stateflow to use uint16_T instead of uint8_T in generated code?
Hi, Yes the "Hardware Implementation" parameter in the model configuration can be used for this purpose. Choose Custom process...

2年以上 前 | 0

回答済み
how to call a function from stateflow within model reference block.
Hi, You can define the common function in the top level model as simulink function, configure its visibility to "Scoped". In t...

2年以上 前 | 0

送信済み


Simulink Function and Referenced Models
Calling Simulink function across the referenced models

2年以上 前 | ダウンロード 2 件 |

回答済み
my simple scheduler not working in stateflow
Hi, Please change the solver type to Fixed Step and explicitly define the step size. When the variable step solver is selected...

2年以上 前 | 0

回答済み
vector variable from Simulink to Stateflow
Hi, While defining the vector input of Stateflow, configure the size as -1. The above setting will be enough to index an eleme...

2年以上 前 | 0

回答済み
Simulation Stop time as a constant input to state flow.
Hi, Create a parameter in the workspace as shown in figure and link the parameter inside the constant block Thanks.

2年以上 前 | 0

回答済み
How to assign values to all the elements of a matrix in Stateflow action language?
Hi, For charts with "Matlab" as action language A=[1 2 3; 4 5 6; 7 8 9] can be directly used whereas for the charts with "C" as...

2年以上 前 | 0

回答済み
How can I use data size of the message in stateflow?
Hi, For a Stateflow with C action language, to index arrays square brackets should be used. Ex: M.data[0] Thanks

2年以上 前 | 0