photo

Benjamin


Aalborg Universitet

2011 年からアクティブ

Followers: 0   Following: 0

統計

  • First Review
  • 3 Month Streak
  • Thankful Level 3

バッジを表示

Feeds

表示方法

回答済み
Matlab Database gives Java exception
Thanks! Worked :)

9年弱 前 | 0

質問


Matlab Database gives Java exception
I have used the Matlab Database toolbox for a long time but today it suddenly fails. If I go go Apps>Database Explorer I get the...

9年弱 前 | 2 件の回答 | 0

2

回答

回答済み
How to change all variable names in a Matlab function?
Thanks for this great suggestion, Guillaume. As I see it, the parser you suggest is able to find all variable names in the f...

9年弱 前 | 0

質問


How to change all variable names in a Matlab function?
I would like to have a method for duplicating a function and at the same time rename all variables in the file so that they have...

9年弱 前 | 3 件の回答 | 0

3

回答

回答済み
How to implement a pipe function as in F# (|>) or in R (%>%)
Thanks a lot for all the answers! As to whether the pipe notation is easier to ready, I guess it depends on what you are used...

9年弱 前 | 0

質問


How to implement a pipe function as in F# (|>) or in R (%>%)
I use R from time to another and really love the functionality to have the pipe function in R. Has there been any thoughts on im...

9年弱 前 | 4 件の回答 | 1

4

回答

質問


sendmail() gives Network is unreachable error on one of my computers
I have two PCs both with Matlab R2014a installed. The following code: setpref('Internet','SMTP_Server','my_smtp'); setpr...

約9年 前 | 1 件の回答 | 0

1

回答

質問


How to plot two plotyy plots in the same plot
I am trying to plot four plots in the same figure. First i plot using plotyy. Then two graphs are created, each with a yaxis. ...

約9年 前 | 3 件の回答 | 0

3

回答

質問


Dynamic number of Simulink blocks, is it possible?
Is it possible to have simulink model that contains a dynamic number of blocs? E.g. have a model that creates N simulink subsyst...

13年以上 前 | 1 件の回答 | 0

1

回答

質問


How to sample and process signals of a given length in Simulink
I have to calculate the correlation of a signal x in Simulink: Exx = 0; for t=1:size(x,1) Exx = Exx + x(:,t)*x(:...

13年以上 前 | 2 件の回答 | 0

2

回答

質問


How to make static variable in Simulink
I have several identical simulink models, where only the parameters vary: Simulink block 1 uses the variables x.a{1}, x.b{1}, x...

13年以上 前 | 1 件の回答 | 0

1

回答

回答済み
Saving/Loading the SimState Programmatically
Thanks for quick response :) I changed the code into simOut = sim(simfile,'StopTime',num2str(10),'SaveFinalState','on','Fi...

13年以上 前 | 1

| 採用済み

質問


Saving/Loading the SimState Programmatically
I have a problem with saving/loading SimState programmatically. It works when i do it manually in the Simulink settings, but whe...

13年以上 前 | 2 件の回答 | 0

2

回答