Community Profile

photo

ashwinee jadhao


2019 年からアクティブ

統計

  • Knowledgeable Level 1
  • Revival Level 1
  • First Answer

バッジを表示

Content Feed

表示方法

質問


PIL block not build for C2000
Hello, I am working on simulink, want to generate PIL block from the subsystem. whenever I tried to generate PIL block I am get...

約5年 前 | 0 件の回答 | 0

0

回答

回答済み
The PIL simulation reports an error, and the host and target board subdata types do not match. How to solve this problem, I am using the PIL module generated by stateflow, the input and output type of defining the stateflow data is double
You might be using 4byte hardware and sending data of 8byte. Change you data into 4byte. Please give me more details

約5年 前 | 0

| 採用済み

回答済み
eCAN loading problems to TI C2000 C28x3x card; are example only for Vector hardware
can I use thiosn VN1610 for testing PIL using CAN COMMUNICATION

約5年 前 | 0

質問


How to use PIL model by using EXTERNAL MODE as CAN instead of serial
Hello, I am using PIL in simulink. Created Plant model running in software and controller model running as PIL block in hardwar...

約5年 前 | 0 件の回答 | 0

0

回答

質問


Build process completed successfully Error evaluating registered method 'Start' of MATLAB S-Function 'sserialcb' in 'TRANSMIT1/Serial Configuration'. Caused by: Open failed: Cannot connect to the COM6 port. Possible reasons are another application is
I am facing this error while doing SCI transmit data. simulink scenario is shown here. Let me know I am doing anything wrong? ...

約5年 前 | 2 件の回答 | 0

2

回答

質問


not able to transmit data serially
Hello, I am doing serial communication using SCI block. But it is not transmitting any value. I have used MSO at the SCIB port...

約5年 前 | 0 件の回答 | 0

0

回答

質問


TMS320F28069M: File C:\ProgramData\MATLAB\SupportPackages\R2018b\toolbox\target\supportpackages\tic2000\registry\thirdpartytools\thirdpartytools_win64.xml not found
I am using c2000 with simulink , my prgram is working good in normal mode but while going to execute in external mode it shows t...

約5年 前 | 1 件の回答 | 0

1

回答

質問


Error using coder.oneclick.TargetHook/extModeConnect (line 178) Error occurred while executing External Mode MEX-file 'ext_comm': ExtSetTargetPkt() call failed for ExtSendGenericPkt(). Ensure target is still running Error in coder.oneclick.CoderTar
I am doing SCI communication and while debuging code into hardware get successfully debug and then get automatically abort. It g...

約5年 前 | 0 件の回答 | 0

0

回答

質問


Why not able to set comp port in serial communication block
It giving error - error is occures while evaluating apply callback

約5年 前 | 1 件の回答 | 0

1

回答

質問


ExtTargetPktPending() call failed while checking for target pkt
I am getting error Error occurred while executing External Mode MEX-file 'ext_comm': ExtTargetPktPending() call failed while...

約5年 前 | 2 件の回答 | 0

2

回答

質問


Error evaluating registered method 'Start' of MATLAB S-Function 'c2000hostsci_setup' in 'TRANSMIT/SCI Setup'. The following is the MATLAB call stack (file names and line numbers) that produced this error: ['C:\Program Files\MATLAB\R2018b\toolbox\ta
Error evaluating registered method 'Start' of MATLAB S-Function 'c2000hostsci_setup' in 'TRANSMIT/SCI Setup'. The following is t...

約5年 前 | 1 件の回答 | 0

1

回答

質問


how to execute SCI communication
Hello, I am working on simulink platform and want to communicate two TMS320F28069M LAUNCHPAD using SCI communication. I have us...

約5年 前 | 1 件の回答 | 0

1

回答

質問


how t generate software interrupt for C2000 in simulink, and connect with states
I am using stateflow in simulink. I want to give software interrupt and as per that interrupt status wants to changes status and...

約5年 前 | 0 件の回答 | 0

0

回答