統計
MATLAB Answers
0 質問
8 回答
ランク
of 157,897
コントリビューション
0 問題
0 解答
スコア
0
バッジ数
0
コントリビューション
0 投稿
コントリビューション
0 パブリック チャネル
平均評価
コントリビューション
0 ハイライト
平均いいねの数
Feeds
回答済み
Simulink Test baseline data from excel
I guess there can be two ways to fix this. Change "Out1" to "Out1:1" in the excel file so that the signal name matches with what...
Simulink Test baseline data from excel
I guess there can be two ways to fix this. Change "Out1" to "Out1:1" in the excel file so that the signal name matches with what...
7年以上 前 | 1
| 採用済み
回答済み
Simulink Test - Test Sequence Autocomplete Issue
Apologies for the very very late response. Tab completion has been added in R2016a. From R2016a release notes: The Test Seque...
Simulink Test - Test Sequence Autocomplete Issue
Apologies for the very very late response. Tab completion has been added in R2016a. From R2016a release notes: The Test Seque...
8年弱 前 | 0
| 採用済み
回答済み
How to access streamed signals for custom criteria in Simulink Test?
I assume you are using R2016b or earlier when streamed and logged signals were handled differently. You can use the following co...
How to access streamed signals for custom criteria in Simulink Test?
I assume you are using R2016b or earlier when streamed and logged signals were handled differently. You can use the following co...
8年弱 前 | 1
回答済み
What causes the error: "Could not append child which had existing parent" when trying to generate a report via Test Manager
Please take a look at this bug report: <https://www.mathworks.com/support/bugreports/1545180> There is a patch attached to t...
What causes the error: "Could not append child which had existing parent" when trying to generate a report via Test Manager
Please take a look at this bug report: <https://www.mathworks.com/support/bugreports/1545180> There is a patch attached to t...
8年弱 前 | 1
| 採用済み
回答済み
Code Coverage with Simulink Test
Starting 16a, you can collect model and code coverage from your tests in Simulink Test Manager: <http://www.mathworks.com/help/...
Code Coverage with Simulink Test
Starting 16a, you can collect model and code coverage from your tests in Simulink Test Manager: <http://www.mathworks.com/help/...
8年以上 前 | 0
回答済み
Test Manager Visualize Results only plots 10 seconds
Which release are you using? Select the axes and press spacebar to "fit to view". It is possible that the axes limits are less t...
Test Manager Visualize Results only plots 10 seconds
Which release are you using? Select the axes and press spacebar to "fit to view". It is possible that the axes limits are less t...
8年以上 前 | 0
回答済み
How can I create Baseline Criteria In Test Manager
You need to capture baseline data for creating baseline criteria. There are a couple of ways you can do this. You need to first ...
How can I create Baseline Criteria In Test Manager
You need to capture baseline data for creating baseline criteria. There are a couple of ways you can do this. You need to first ...
約9年 前 | 0
回答済み
Testing large-scale models in SIMULINK
For testing Simulink models, there are a few features in Simulink which might help you: # Signal logging in Simulink: <ht...
Testing large-scale models in SIMULINK
For testing Simulink models, there are a few features in Simulink which might help you: # Signal logging in Simulink: <ht...
11年以上 前 | 1
| 採用済み