Chen correlation wall temperature calculation

Calculation of pipe wall temperature using the 1963 Chen correlation for subcooled boiling flow
ダウンロード: 656
更新 2013/10/21

ライセンスの表示

This function uses the 1963 Chen correlation for subcooled boiling flow to calculate the wall temperature of a pipe, based on inlet pressure, an initial guess of the pressure at the pipe wall, and three constants: A, B, C
A = h_pb*S, h_pb is the pool boiling coefficient, and S is the Chen suppression factor
B = h_c, h_c is the forced convection coefficient
C = h_c*(Tsat - Tbulk) - q'', Tsat is the saturation temperature of the water in the pipe at the inlet pressure, Tbulk is the temperature of the bulk fluid, q'' is the heat flux of the pipe to the fluid.
This function makes use of the Steam Tables uploaded by Magnus Holsten.

引用

Danyal Mohaddes Khorassani (2024). Chen correlation wall temperature calculation (https://www.mathworks.com/matlabcentral/fileexchange/44014-chen-correlation-wall-temperature-calculation), MATLAB Central File Exchange. に取得済み.

MATLAB リリースの互換性
作成: R2012b
すべてのリリースと互換性あり
プラットフォームの互換性
Windows macOS Linux
カテゴリ
Help Center および MATLAB AnswersFluid Network Interfaces Library についてさらに検索
謝辞

ヒントを得たファイル: X Steam, Thermodynamic properties of water and steam.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!
バージョン 公開済み リリース ノート
1.0.0.0