Why does the runtime API in Simulink output a empty signal at the output of an atomic subsystem in Simulink version 6.4(R2006a)?

1 回表示 (過去 30 日間)
I have an atomic subsystem called 'MYSUB' in my simulink model 'MYMODEL' and I execute the following code on the MATLAB command prompt.
rto = get_param('MYMODEL\MYSUB', 'runtimeobject') % gcb is an atomic subsystem
op = rto.OutputPort(1);
mydata=op.data;
The output port data 'mydata' is empty although a valid signal is propagated to the output port.

採用された回答

MathWorks Support Team
MathWorks Support Team 2009 年 6 月 27 日
This enhancement has been incorporated in Release 2009a (R2009a). For previous product releases, read below for any possible workarounds:
For previous releases, as a workaround, one can connect another block, e.g. an outport block to the output of the subsystem and use the RunTimeObject of that block.

その他の回答 (0 件)

カテゴリ

Help Center および File ExchangeIterator Subsystems についてさらに検索

製品


リリース

R2006a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by