Is there any possibility to directly use varibles from a linked data-dictionary in a subcircuit which is modeled using Plecs Blockset? For all other native Simulink subcircuits this is no problem by just specifying the variable name as Parameter, but Simulink Blockset always throws the following error:
Error evaluating parameter '<parameterName>' in component MainCircuit/PlecsCircuit/Component: Unrecognized function or variable '<variableName>'.Error
So, obviously the Plecs circuit is not able to access the linked data dictionary. Is there any option or work around to get access to the variables stored in the dictionary?

採用された回答

Johann Asam
Johann Asam 2021 年 8 月 20 日
編集済み: Johann Asam 2021 年 8 月 20 日
Actually I found a solution:
You can modify the mask of the plecs subsystem. There you would need to add an edit field for each variable and enter as name and as well as default value the name of the variable in the data dictionary. Then the specified dictionary variables are also available in the Plecs environment, although the edit fields will not be accessible from the subcircuit Block Parameters