Hey Guys
i want to set Model Callbacks of my Simulink Model with a Simulink bock. I want to make a body-Collision Library. To check for Body Collision, i use the InitFcn and StopFcn to detect body collision. If its possible i want to add a block to my library that automatically sets the InitFcn and StopFcn if i place it in a Simulink model.

回答 (1 件)

Tejas
Tejas 2024 年 4 月 26 日
Hello Marcus,
My understanding from above question is that you want a block, placed inside the Simulink model to establish InitFcn and StopFcn callbacks.
Try this simple method to accomplish this:
  • Begin by creating an empty subsystem block. Position it at the preferred spot within the model.
  • Within the ‘InitFcn’ callback of the Subsystem, use ‘set_param’ command to establish ‘InitFcn’ and ‘StopFcn’ callbacks of the model. Provide model name, callback name and the code to be written inside of callback, as an input to ‘set_param’ command. The ‘set_param’ command will then establish these callbacks.
  • Below is an example of the code for reference.
Here is a screenshot displaying the ‘InitFcn’ callback, successfully configured using the ‘set_param’ command.
Following, a screenshot illustrates the ‘StopFcn’ callback, also effectively established through the ‘set_param’ command.
For more information on set_param command and the Callbacks used, please refer to these documentations: