SimPower Systems (PSB): discrete analysis
1 回表示 (過去 30 日間)
古いコメントを表示
When using Simulink with SimPower Systems blockset (PSB) you have to use a block called "powerGUI".
There you can specify a sample time, when simulation type is discrete.
Still you can choose another sample time or even continuous solver in "normal" simulink 'Model Configuration Parameter' window.
Will there be a cont. or discrete analysis ? What's the difference between those two options ? Why do I need them both ?
0 件のコメント
回答 (1 件)
Sabin
2022 年 12 月 20 日
This is like using a Simulink discrete block while setting the global solver to variable-step. The power systems part would be discrete if a discrete rate is selected. But some parts of the model might still run in continuous time (controlled by the global solver) if continuous Simulink blocks are used in the model.
0 件のコメント
参考
カテゴリ
Help Center および File Exchange で Electrical Sensors についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!