How to use external simulation time in simulink?

Hello :)
I have sensors and pumps that are connected to a board which has a tcp connection to simulink. Since round times from simulink to the board and back are too long and flickers a little, the control algorithm is executed on the board. It sends data back to simulink after every execution (20 ms) and a time stamp at which the data was sent. I would like to use this time stamp as simulation time to have the data shown correctly in a scope even if they arrived with different latency or maybe even different order. Is there any way to achieve that?

回答 (1 件)

Fangjun Jiang
Fangjun Jiang 2021 年 3 月 4 日

0 投票

USE "XY Graph" block. X is the received time, Y is the received data.

2 件のコメント

Jan Theiss
Jan Theiss 2021 年 3 月 16 日
編集済み: Jan Theiss 2021 年 3 月 16 日
That solves the problem of displaying it correctly. But what if other blocks should use that as their simulation time to calculate other things? Maybe by using a shorter sim interval and delay the simulation so that it matches the received time?
It is a little hard to me to find the right way between discrete simulation of continous signals...
Fangjun Jiang
Fangjun Jiang 2021 年 3 月 16 日
That is the "latency" you have to deal with. You can slow down the simulation on the computer or "wait" for the message coming from TCP/IP. But there is no other way better than reducing this "latency" directly if possible.