PMSM (simscape) No load test

9 ビュー (過去 30 日間)
youjarr
youjarr 2021 年 1 月 29 日
移動済み: DGM 2023 年 2 月 1 日
Hey guys,
I am trying to resolve my no load data out of my in simscape designed PMSM.
With load it is no problem and the motor is working properly. I am using a ideal torque source for my load simulation.
But when I type in 0 the motor is not working properly.
So how can I do a no load test with the PMSM.
A open circuit is not the right thing at this place because it uses high (inf) resistances and I am not able to get my no load current.
Maybe one of u tried this before... I hope so.
Best regards and thanks in advance.
  3 件のコメント
Federico Manfrin
Federico Manfrin 2021 年 4 月 15 日
I think you're using the PMSM as voltage/current generator, right?
Mohammad
Mohammad 2023 年 2 月 1 日
移動済み: DGM 2023 年 2 月 1 日
Could you find the right answer for how to get torque in PMSM in no load?

サインインしてコメントする。

回答 (1 件)

Joel Van Sickel
Joel Van Sickel 2021 年 8 月 17 日
If you are using specialized power systems, it can be very hard to model a no-load test without very small time steps. It might make more sense to use the simscape components (blue components) to model this. You can also use a large snubber resistor to get "almost" no load current. Esentially, the smaller your time step, or the lower your resistance, the easier it will be to get a value.

カテゴリ

Help Center および File ExchangeSimscape Electrical についてさらに検索

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by