Torque and Rotational motion sensor in simscape

90 ビュー (過去 30 日間)
Leonardo Costa
Leonardo Costa 2020 年 12 月 23 日
コメント済み: 彬 魏 2021 年 9 月 21 日
I have an issue in connecting an ideal torque sensor and an ideal rotational sensor to my BLDC motor.
I saw a lot of question and everybody says that the problem is put in parallel this two sensors. But i cannot fully understand the meaning.
Could you please answer with some photo about the differences?
I add a photo of my situation, honestly I cannot see a different way to use this two sensors together.
Thank you in advance
  1 件のコメント
Hyunuk Ha
Hyunuk Ha 2020 年 12 月 31 日
Simscape is multi-domain plant modeling tool, and each domain has its own variables, which defines power.
In the mechanical rotational domain, two variables are angular velocity and torque.
So, you can detect angular velocity or torque from that domain.
You can refer to the detailed info. at :

サインインしてコメントする。

回答 (1 件)

Juan Sagarduy
Juan Sagarduy 2021 年 1 月 4 日
Hi Leonardo
Torque is a through variable measured with a torque sensor (TS) in series with the shaft of the motor. Speed is an across variable (potential) measured with a rotational sensor (Rot S) in parallel.
In your case, if S is the shaft of the motor, the connection is S - (TS - port R) - (TS - port C) - (Rot S - port R) - mechanical load (inertia, torque source...) (Rot S - port C) connected to a mechanical reference is correct.
Hope this helps out Regards Juan
  3 件のコメント
彬 魏
彬 魏 2021 年 9 月 21 日
彬 魏
彬 魏 2021 年 9 月 21 日
The issue was due to the torque sensor being connected incorrectly. In the rotational domain, angular velocity is the across variable and torque is the through variable. The velocity sensor measures the change in velocity across R and C without any torque going through the sensor. On the other hand, the torque sensor measures the torque going through the sensor without any change in velocity across R and C. In the not working model, the torque sensor connection means that the velocity at the junction is the same as the mechanical reference, which is zero velocity. That is why the results are wrong.
If the intent is to measure net torque on the hydraulic machine, then the torque sensor should be connected between the machine and the junction point (like how you would connect a hydraulic flow rate sensor).
This was the cause for a* very specific* model. If you cannot resolve your issue by going through the Simscape documentation and you have a valid license with maintenance, then please contact Technical Support.

サインインしてコメントする。

カテゴリ

Help Center および File ExchangeParameterization Methods についてさらに検索

製品


リリース

R2020b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by