why did you use 60000 on the fuel cell stack model on utilsation equations?

回答 (1 件)

Joel Van Sickel
Joel Van Sickel 2020 年 12 月 11 日
Hello Leo, I assume this is in reference to the equations under the hood: 60000*FC.Nc*u(2)*FC.R*u(5)/(FC.z*FC.F*u(4)*FC.Pstd*u(3)*u(1))
From the docuentation on this block:
The 60000 constant comes from the conversion from the liter/min flow rate used in the model to m3/s (1 liter/min = 1/60000 m3/s).