Fuel cell stack model equations. why 60000 on stack utilisation equation?

why did you use 60000 on the fuel cell stack model on utilsation equations?

回答 (1 件)

Joel Van Sickel
Joel Van Sickel 2020 年 12 月 11 日

0 投票

Hello Leo, I assume this is in reference to the equations under the hood: 60000*FC.Nc*u(2)*FC.R*u(5)/(FC.z*FC.F*u(4)*FC.Pstd*u(3)*u(1))
From the docuentation on this block:
The 60000 constant comes from the conversion from the liter/min flow rate used in the model to m3/s (1 liter/min = 1/60000 m3/s).