Why doesn't signal units propagate through blocks?

1 回表示 (過去 30 日間)
Proglet
Proglet 2020 年 10 月 31 日
コメント済み: Walter Roberson 2020 年 11 月 1 日
I just started to use the "signal units" feature on Simulink signals then I found that it doesn't go through my model. For example, I expect a signal in "Nm" of the output of a product block which has inputs of signals in "N" and "m". But it doesn't happen.
Am I missing something?

採用された回答

stozaki
stozaki 2020 年 10 月 31 日
Hello Proglet,
There are two inputs. One has the unit N and the other has the unit m. The unit Nm is obtained as the result of each multiplication.
However, the Product block does not automatically add units to the calculation result. This is a Simulink specification. If you want to give the unit explicitly, you need to set the unit attribute using Simulink.Signal object etc.
stozaki
  2 件のコメント
Proglet
Proglet 2020 年 11 月 1 日
Thank you for your reply.
Now I know this feature is for not calculation consistency checking but subsystem connection checking.
Walter Roberson
Walter Roberson 2020 年 11 月 1 日
Simscape checks units I believe.

サインインしてコメントする。

その他の回答 (0 件)

カテゴリ

Help Center および File ExchangeModel Verification についてさらに検索

タグ

製品


リリース

R2019b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by