Simulink cannot propagate the variable-size mode from the output port
22 ビュー (過去 30 日間)
古いコメントを表示
Hello everyone,
I'm gettinng a varaible sized mode ouput from a matlab function block which i give to postions(x,y,z) to a demux . but it expects a fixed mode input to the demux . can you please check my simulink blocks and function in the picture.
1 件のコメント
Rhea Chandy
2020 年 10 月 12 日
Hi Joysen
I'm trying to recreate the issue on my end. I would appreciate it if you can share your simulink model so that I can get a closer look at the blocks.
回答 (1 件)
Rhea Chandy
2020 年 10 月 12 日
I understand that you want to use a variable-sized mode output from a function block as the input for a demux. One of the block characteristics of demux is that it does not currently support inputs from variable-size signals.
One possible workaround is to use a Bus Selector block which does support propagation of variable-size signals.
0 件のコメント