Compare data at consecutive timesteps during runtime in Simulink
5 ビュー (過去 30 日間)
古いコメントを表示
Hi all,
I'm trying to create a parachute model system for a rocket that will deploy when the altitude begins to decrease i.e. altitude at timestep n < altitude at timestep n-1.
I'm not entirely sure what the best way is to do this. I've played around with setting the altitude as a parameter of a masked subsystem but this didn't really work and made the simulation run significantly slower. Is there a fast way to extract a previous value of a logged signal?
Thanks!
0 件のコメント
採用された回答
Fangjun Jiang
2020 年 8 月 26 日
Use a Unit Delay block, the input is altitude, the output is the "previous value" of the altitude.
0 件のコメント
その他の回答 (0 件)
参考
カテゴリ
Help Center および File Exchange で Creating Custom Components and Libraries についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!