System Identification Toolbox: How can we modify the starting parameters for the armax-algorithm?

1 回表示 (過去 30 日間)
One can calculate ARMA-coefficients using the armax-algorithm from the Systems Identification Toolbox:
estimatedPolymodel=armax(iddata(outputdata,inputdata,tsample),[na nb nc nk], opt);
ARcoeff=estimatedPolymodel.A
MAcoeff=estimatedPolymodel.B
How can we modify the starting parameters for the algorithm (to accelerate and improve the results)?

採用された回答

Rajiv Singh
Rajiv Singh 2020 年 6 月 15 日
You can set the A, B, C values explicitly, as in
estimatedPolymodel.A = ARCoeff
Or, call the IDPOLY constructor with A, B, C polynomials initialized to the desired values.
A = [1 .1]
B = [0 0 4 1]
C = [1 .3]
m = idpoly(A,B,C,'Ts',1)
% refine model's initial parameter values
m2 = armax(data, m)
% but I wanted to update only A and B but not C!
m.Structure.C.Free = false;
m3 = armax(data, m)
  2 件のコメント
Urs Hackstein
Urs Hackstein 2020 年 8 月 10 日
Dear Rajiv Singh,
thank you very much for your prompt and precise answer which explains how to set fixed values as start parameters for A, B and C. But how can you define intervals of constraint for A, B or C, e.g.
?
Rajiv Singh
Rajiv Singh 2020 年 8 月 10 日
Look under the "structure" property. In addition to "Free", it also offers "Minimum" and "Maximum" specifications that you can set for individual coefficients.

サインインしてコメントする。

その他の回答 (0 件)

カテゴリ

Help Center および File ExchangeLinear Model Identification についてさらに検索

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!