How to create/ simulate fault in asynchronous machine in simulink?

2 ビュー (過去 30 日間)
elbordj mohamed
elbordj mohamed 2020 年 5 月 9 日
回答済み: Sabin 2025 年 1 月 30 日
How can I simulate the faults in the asynchronous machine ?ex: broken bar or stator winding.

回答 (1 件)

Sabin
Sabin 2025 年 1 月 30 日
Normally we can model electrical machines by representing each winding as a single entity with associated inductance, electromotive force, and mutual inductive coupling to adjacent windings. However, when a winding fault occurs, the single entity assumption breaks down. To correctly capture the resulting dynamics, you have to model the motor at a winding slot level. This requires modeling in the magnetic domain. Simscape Electrical has an example of a faulted PMSM that may be used as a starting point:

カテゴリ

Help Center および File ExchangeElectrical Block Libraries についてさらに検索

製品

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by