How can I simulate the faults in the asynchronous machine ?ex: broken bar or stator winding.
0 件のコメント
回答 (1 件)
Sabin
2025 年 1 月 30 日
Normally we can model electrical machines by representing each winding as a single entity with associated inductance, electromotive force, and mutual inductive coupling to adjacent windings. However, when a winding fault occurs, the single entity assumption breaks down. To correctly capture the resulting dynamics, you have to model the motor at a winding slot level. This requires modeling in the magnetic domain. Simscape Electrical has an example of a faulted PMSM that may be used as a starting point: