Svpwm 2 error block on the Equivalent model
4 ビュー (過去 30 日間)
古いコメントを表示
Hi, I'm trying to simulate this circuit on simunlink and I got these two errors on the equivalent model
I'm not sure what is the problem here ; it says "error in port dimensions"
Block error simulink : input is a one dimentional vector with 6 elements

0 件のコメント
回答 (1 件)
Sabin
2023 年 3 月 13 日
編集済み: Sabin
2023 年 3 月 13 日
Looks like the problem is in the Universal Bridge. The dimension of 'g' input is expected to be 6 as we have 6 switching devices in a three-phase inverter. However, in the attached image the input 'g' is connected to a Pulse Generator that outputs only a pulse. Probably it is better to use a PWM Generator that would output 6 pulses.
0 件のコメント
参考
カテゴリ
Help Center および File Exchange で Electrical Block Libraries についてさらに検索
製品
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!