Svpwm 2 error block on the Equivalent model

4 ビュー (過去 30 日間)
OUERDANE Fethi
OUERDANE Fethi 2020 年 4 月 28 日
編集済み: Sabin 2023 年 3 月 13 日
Hi, I'm trying to simulate this circuit on simunlink and I got these two errors on the equivalent model
I'm not sure what is the problem here ; it says "error in port dimensions"
Block error simulink : input is a one dimentional vector with 6 elements

回答 (1 件)

Sabin
Sabin 2023 年 3 月 13 日
編集済み: Sabin 2023 年 3 月 13 日
Looks like the problem is in the Universal Bridge. The dimension of 'g' input is expected to be 6 as we have 6 switching devices in a three-phase inverter. However, in the attached image the input 'g' is connected to a Pulse Generator that outputs only a pulse. Probably it is better to use a PWM Generator that would output 6 pulses.