PID BLOCK IN SIMULINK

15 ビュー (過去 30 日間)
Uzair Akhtar
Uzair Akhtar 2020 年 4 月 13 日
コメント済み: Ameer Hamza 2020 年 4 月 14 日
I have worked out that my PID controller is
Gc = 4.2(1 + 1/1.57s + 0.39s)
I want to put this into a block on simulink but the PID controller block in simulink is in a weird form. Does anyone know how to get around this. Thanks.

採用された回答

Ameer Hamza
Ameer Hamza 2020 年 4 月 13 日
In the Simulink PID block, In the form field, change the form from parallel to ideal and set the value of filter coefficient N to be quite high (say 200). Then parameters P, I, and D can be used from your current transfer function.
  2 件のコメント
Uzair Akhtar
Uzair Akhtar 2020 年 4 月 13 日
Thank you. Do you know what impact the filter coefficient N has to the system.
Ameer Hamza
Ameer Hamza 2020 年 4 月 14 日
PID block uses a low-pass filter for D term. The value of N controls the stop-band of the low-pass filter. Higher the value of N, higher is the stop-band frequency. For the low-value of N, the PID block will smooth the derivative of your system. If you have a high value of N, the filter will have no significant effect.