Retaining previously held values in simulink
12 ビュー (過去 30 日間)
古いコメントを表示
I have a simulink model that is run using a code in a loop in consecutive time-steps. However, there's a problem, that the model resets itself before each new time-step (loop). I was wondering if there is an option for the model to NOT RESET itself before new iteration, in other words, I want all signals to keep (retain) their last held values from previous iteration. Thanks.
0 件のコメント
回答 (1 件)
Jonas
2020 年 2 月 13 日
編集済み: Jonas
2020 年 2 月 13 日
It is not completely clear to me what your set-up looks like, but you may want to investigate 'Enabled Subsystems'. You can set each output to be 'held' or 'reset' when enabling.
2 件のコメント
Jonas
2020 年 2 月 14 日
I assume that each iteration you do, is running the simulation model, stopping it, and starting it from stratch. What I would do is put the part that you want to iterate inside an Enabled Subsystem but the plant model not. Then you could enable and reset the iterative part that you DO want to reset with a certain clock or trigger. The plant model however just keeps running.
This means that instead of running, stopping and restarting your whole Simulink model, you run it once.