Hardware in Loop Simulation with pixhawk board using Embedded Coder for Px4 toolboxes : The base rate of the Simulink model 0 millisecond is less than 1 millisecond
4 ビュー (過去 30 日間)
古いコメントを表示
I am trying to do Hardware in Loop Simulation with pixhawk board using Embedded Coder for Px4 toolboxes. I am getting the following error in my Simulink model:
The base rate of the Simulink model 0 millisecond is less than 1 millisecond. This is not supported by the PX4 Autopilot since the tick rate of NuttX OS is 1 millisecond.
To fix this error, change sample times of blocks in the Simulink model which is causing the base rate to be 0millisecond.
How do I resolve the issue?
Thanks,
Sajith
3 件のコメント
Yunjie Yang
2021 年 3 月 26 日
Best Regards
Purav Panchal
2021 年 7 月 22 日
I got the same error when simulating. Please have a look if there is a signal builder or some block which is having continuous time rate. Also in the configuration settings -- Code Generation -- Interface -- Uncheck the Continuous Time option if it is checked. This can help to solve the problem.
回答 (1 件)
Arun Mathamkode
2021 年 11 月 11 日
I agree with Purav's suggestion. Please makesure that the base sampletime of your model is greater or equal to 1 millisecond.
0 件のコメント
参考
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!