Ideal switch cannot be used in phasor powergui simulation ? Is there any solution which provide the same function as a gate control switch in phasor simulation ?

回答 (1 件)

Sabin
Sabin 2024 年 1 月 21 日
In Simscape Electrical, when you're using the Phasor simulation mode within the Powergui block, you are limited to certain components that are compatible with phasor analysis. The phasor simulation mode is designed for the frequency domain analysis of electrical power systems operating under steady-state conditions. Because the ideal switch operates in the time domain with instantaneous transitions, it cannot be represented in the frequency domain using phasors.