nonlinear model in simulink and designing pid controller
古いコメントを表示
Hi guys
when I design for a nonlinear model in simulink a pid controller, and I want to run the simulink, it gives me bellow image.
(max step size is 0.2s , please go to configuration parameter and set "automatic solver parametric selection" to "none". although, I do that again it gives me this warning and when I see the scop, it does not give me a good result, it gives me just 0 in output instead of giving 2 things( output and input).
I attach also my slx file.
3 件のコメント
Enrico Anderlini
2019 年 8 月 30 日
The file you have attached has no PID controller.
Anyway, it looks to me that the problem is that you are using an automatic solver, which selects a very large time step. You can disable the warning, but the problem is there. If the time discretisation is too rough, you can select a solver manually. Say ode4 (4th-ordeer Runge-Kutta) with a predefined time step.
azam ghamari
2019 年 9 月 6 日
nor zulaiman
2021 年 1 月 2 日
can i get your simulink pic
回答 (1 件)
Rhea Chandy
2020 年 9 月 29 日
0 投票
It is my understanding that you are having some difficulty in choosing a solver for your model.
The automatic solver recommends a fixed or variable step solver based on your maximum step size. If you’re not satisfied with the results from the auto solver, I suggest manually choosing the solver and comparing the different results with the tradeoffs. For example, decreasing the step size in a fixed-step solver will increase the accuracy of the results but increases the time required to simulate the system.
カテゴリ
ヘルプ センター および File Exchange で PID Controller Tuning についてさらに検索
製品
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!