MATLAB Answers

Input ports (1, Action) If Action Subsystem' are involved in the loop?

60 ビュー (過去 30 日間)
Adit
Adit 2019 年 8 月 20 日
Answered: Divya Yerraguntla 2019 年 9 月 25 日
I am trying to simulate a closed loop cooling system using simulink but facing this error continously.
If anyone can help me with this would be of great help?
I have uploded the file,if anyone can please run it and share the trouble shooting measures willbe of greta help.
I ahve uploded the mat variable file for initialization parameters of the model

  2 件のコメント

Murugan C
Murugan C 2019 年 8 月 21 日
I couldn't able to open the model. Because you designed in Simulink 2017a, So can you please upload 2016b simulink model or below version.
Adit
Adit 2019 年 8 月 21 日
Hi
Thanks for help
I have attached 2016b model here.

サインイン to comment.

件の回答 (1)

Divya Yerraguntla
Divya Yerraguntla 2019 年 9 月 25 日
Hi Adit,
I could see an algebraic loop formed in your model by the signal coming to Total_pressure_BP input of Pump 1 subsystem. This is actually causing the issue. Try adding a Unit Delay block to the signal coming to Total_pressure_BP block.
For more information about identification and removal of algebraic loops have a look at these links:
Also in order to solve algebraic loops in models containing continuous blocks you could go through this link:
Hope it helps!