Why are my simulink initial conditions sometimes not met, despite high priority?
7 ビュー (過去 30 日間)
古いコメントを表示
I set the initial temperature of a Simscape thermal mass to 303K and put a temperature sensor on it. Solver is set to start with steady state. Still, the temperature of this mass is 293 at t=0s and there are no warnings or errors reported in the diagnostics viewer. Large screenshot is attached.
1 件のコメント
Hari Krishna Ravuri
2019 年 7 月 31 日
Hi,
I tried to reproduce the mentioned initial conditions on a simple model and it is working as expected.Please provide the model, so that a workaround may be provided.
回答 (1 件)
Martin
2023 年 10 月 4 日
When selecting Start simulation from steady state, the solver tries to find what the model would go to after a very long simulation. It does not use the initial targets in set in the blocks.
0 件のコメント
参考
カテゴリ
Help Center および File Exchange で Thermal Analysis についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!