Why are my simulink initial conditions sometimes not met, despite high priority?

7 ビュー (過去 30 日間)
Daniel Trapp
Daniel Trapp 2019 年 7 月 24 日
回答済み: Martin 2023 年 10 月 4 日
I set the initial temperature of a Simscape thermal mass to 303K and put a temperature sensor on it. Solver is set to start with steady state. Still, the temperature of this mass is 293 at t=0s and there are no warnings or errors reported in the diagnostics viewer. Large screenshot is attached.tf.PNG
  1 件のコメント
Hari Krishna Ravuri
Hari Krishna Ravuri 2019 年 7 月 31 日
Hi,
I tried to reproduce the mentioned initial conditions on a simple model and it is working as expected.Please provide the model, so that a workaround may be provided.

サインインしてコメントする。

回答 (1 件)

Martin
Martin 2023 年 10 月 4 日
When selecting Start simulation from steady state, the solver tries to find what the model would go to after a very long simulation. It does not use the initial targets in set in the blocks.