When I try to build my stateflow model, I got error "Function call triggered subsystems are not supported for subsystem based code/S-function generation. " What does it mean?
3 ビュー (過去 30 日間)
古いコメントを表示
Here's the error message.
Function call triggered subsystems are not supported for subsystem based code/S-function generation.
Component:Simulink | Category:Build error
An error occurred during subsystem build
Component:Simulink | Category:Build error
Function call triggered subsystems are not supported for subsystem based code/S-function generation.
Caused by:
- Function call triggered subsystems are not supported for subsystem based code/S-function generation.
- Error while generating code for 'Scheduler_table_sim/Scheduler table' in block diagram 'Scheduler_table_sim'
Component:Simulink | Category:Model error
0 件のコメント
回答 (1 件)
Nick Sarnie
2019 年 5 月 18 日
編集済み: Nick Sarnie
2019 年 5 月 18 日
Hi Jenny,
Based on the error, a right-click subsystem build has been performed on a function call subsystem, which is not supported. If this is not the case, can you please share a model which reproduces this issue?
Thanks,
Nick