how to get Beta in power transformation ?

2 ビュー (過去 30 日間)
Saif Zahran
Saif Zahran 2019 年 3 月 3 日
回答済み: Sabin 2025 年 1 月 13 日
I need help
per the diagram, i am designing DQ frame controller for single phase grid connected to H-bridge inverter and LCL filter.
Current Decoupled to alpha which is sine wave, and beta which need to be shiftted by 90 degree.
in above diagram i am using transport delay to shift beta, but this way does not give accurate result.
I need help of any other way to be implemented to get beta with same freauency and amplitude of alpha
Thanks
  1 件のコメント
JANARDHAN GURRAM
JANARDHAN GURRAM 2019 年 12 月 20 日
I am working in the same environment of producing alpha beta to dq for a single phase inverter . I too started with transportation delay but getting ac outputs in d, q profiles when i watch them .I guess they are needed to be dc components .
Have solved your issue.?
Do you find the solution for the same .
Can u please help me in any way .

サインインしてコメントする。

回答 (1 件)

Sabin
Sabin 2025 年 1 月 13 日
In continuous time, to achieve a 90-degree phase shift, you can use a Transport Delay block (or a Variable Transport Delay). The key is to set the delay time to a quarter of the signal's period. You can use a PLL to get the frequency:
Other approaches include but not limited to FIR filter or use complex exponentials.

カテゴリ

Help Center および File ExchangeElectrical Block Libraries についてさらに検索

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by