How is efficiency translated into fluid temperature in Simscape Fluids fixed displacement pump?

1 回表示 (過去 30 日間)
Nick
Nick 2019 年 2 月 27 日
回答済み: Juan Sagarduy 2020 年 12 月 3 日
I am using the Simscape Fluids fixed displacement pump, with a thermal liquid. I looked through the documentation and could not find any explanation of how mechanical and volumetric efficiencies affect the fluid temperature. I am using "Input Efficiencies" block choice. When I reduce mechanical efficiency, the temperature of the outlet liquid increases, but not by as much as I would expect it to if 100% of the friction torque were added to the fluid. Is some of it assumed to be dissipated to the air? Similarly, when I reduce volumetric efficiency, the temperature increases, is this due to a fluid shearing effect? Are these equations documented anywhere?
I am working on a model where I need to account for all energy streams, so if some of the heat is assumed to go somewhere other than the thermal liquid, I need to account for it separately.

回答 (1 件)

Juan Sagarduy
Juan Sagarduy 2020 年 12 月 3 日
Hi Nick
The documentation explains well the equations behind the fixed displacement pump TL and losses. See the link below:
https://se.mathworks.com/help/physmod/hydro/ref/fixeddisplacementpumptl.html
Br Juan