Relation between flux linkage and voltage constant | power_PMSy​nchronousM​achinePara​ms

Hello to everyone,
I am currently working on mathematical modeling of permanent magnet synchronous motor and stuck in computing some variables from standart manufacturer specifications.
Actually, I want to understand how can I compute flux linkage from Back EMF (Ke) constant.
In Simulink, the Permanent Magnet Synchronous Machine block (Simulink Library -> Simscape/Power Systems/Specialized Technology/Fundamental Blocks/Machines), under the Advanced tab, there is a GUI which name is "Compute from standard manufacturer specifications". In this GUI, I am able to understand the math beyond the Voltage constant (ke) transformations between Vpeak/kRPM and Vrms/(rad/s). But I can't understand how the "flux linkage established by magnets (V*s)" is calculating from this voltage constant value.
Unfortunately, there is no information in Help section of this block about this topic.
Can someone please explain this relation by mathematical derivations.
Thanks in advance.
Best Regards,
Yasin

 採用された回答

Yasin Cetin
Yasin Cetin 2019 年 2 月 23 日

0 投票

ramesh.PNG
solved, thanks.

4 件のコメント

Jacob
Jacob 2023 年 4 月 25 日
seems correct.
Using the above equation and data, where omega M = 1 and 4 pole pairs
flux linkage = sqrt(2)/sqrt(3)*0.03133/(4*1) = 0.0063952
Mohammad Nair
Mohammad Nair 2024 年 4 月 19 日
Could you please specify the source for this?
Radek
Radek 2024 年 5 月 1 日
編集済み: Radek 2024 年 5 月 1 日
Why divide by sqrt(3) if voltage is already stated as rms? And then why multiply by sqrt(2)?
Radek
Radek 2024 年 5 月 1 日
編集済み: Radek 2024 年 5 月 1 日

サインインしてコメントする。

その他の回答 (3 件)

armorfid
armorfid 2023 年 10 月 2 日
編集済み: armorfid 2023 年 10 月 2 日

1 投票

The exact relationships between voltage constant Ke [V/krpm], torque constant Kt [N·m/A], and flux linkage λpm [V·s] are described on this page: https://www.mathworks.com/help/mcb/ref/surfacemountpmsm.html
These are valid for both surface and interior PMSM.

2 件のコメント

Radek
Radek 2024 年 5 月 1 日
Why mathworks divides Ke based on peak voltage by sqrt(3) ? That implies RMS regime. But RMS is meanigless in FOC theory.
At least I can exaplin the 2/3 term seems they can be exaplained by from adding https://e2e.ti.com/support/microcontrollers/c2000-microcontrollers-group/c2000/f/c2000-microcontrollers-forum/298101/torque-calculation-and-definition-of-flux-unit-v-hz/1043212#1043212
Radek
Radek 2024 年 5 月 1 日
Also, here mathworks doesn't use sqrt(3) https://www.mathworks.com/help/sps/ug/parameterize-a-permanent-magnet-synchronous-motor.html. But they talk about Voltage peak to ground.
And the voltage between line conductors is 3 times the phase conductor to neutral voltage, so I guess that is what is happening. V_L-L is converted to V_L-N.

サインインしてコメントする。

Yasin Cetin
Yasin Cetin 2019 年 2 月 20 日
編集済み: Yasin Cetin 2019 年 2 月 20 日

0 投票

Hello again,
I found at the bottom of the following link
"As expected, the measured torque and back EMF constants have approximately the same value (0.18) and are related to the permanent magnet flux linkage via the number of pole pairs N of the motor:
flux linkage = (back EMF constant)/(number of pole pairs)"
But, in the GUI which I mentioned above post, results are not satisfying this equation. (0.03133/0.00639521 = 4.899)
Kadir Akgül
Kadir Akgül 2019 年 6 月 22 日

0 投票

I have same problem. Did you solve the problem?