Simulink integrator block initial conditions
1 回表示 (過去 30 日間)
古いコメントを表示
Hi, How does one specify initial conditions in simulink integrator block for times not t= 0 for example, y(3) =5;
0 件のコメント
採用された回答
Fangjun Jiang
2019 年 2 月 5 日
utilize the "External reset" (set as rising) and "Initial ocndition source" (set as external).
Compare clock with t=3 and make it as the "External reset" signal.
4 件のコメント
Fangjun Jiang
2021 年 4 月 23 日
Compare Clock with Constant block (value is 3) using the Relational Operator block, the output is trur or false.
Wang Tao
2021 年 4 月 24 日
Thanks for the prompt reply! I can get the answer for the time after t=3 with the y(3)=5 now. But the problem is for the time earilier than 3 as t<3, is not correct.
I am handling some two point boundary value problem, which y(3)=5 is the end/ final condition. Is there any way to solve this.
It seems can change the initial setting of integrator through properties, but there are no final condition settings.


その他の回答 (0 件)
参考
カテゴリ
Help Center および File Exchange で Sources についてさらに検索
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!