Hi, How does one specify initial conditions in simulink integrator block for times not t= 0 for example, y(3) =5;

採用された回答

Fangjun Jiang
Fangjun Jiang 2019 年 2 月 5 日
utilize the "External reset" (set as rising) and "Initial ocndition source" (set as external).
Compare clock with t=3 and make it as the "External reset" signal.
  4 件のコメント
Fangjun Jiang
Fangjun Jiang 2021 年 4 月 23 日
Compare Clock with Constant block (value is 3) using the Relational Operator block, the output is trur or false.
Wang Tao
Wang Tao 2021 年 4 月 24 日
Thanks for the prompt reply! I can get the answer for the time after t=3 with the y(3)=5 now. But the problem is for the time earilier than 3 as t<3, is not correct.
I am handling some two point boundary value problem, which y(3)=5 is the end/ final condition. Is there any way to solve this.
It seems can change the initial setting of integrator through properties, but there are no final condition settings.