FIR Parks-McClellan
4 ビュー (過去 30 日間)
古いコメントを表示
Hi,
I have a set of FIR Parks-McClellan coefficient :
Numerator: FR_SV = [3.91719822748777E-02, 0.103629842929331, 0.171922134825388, 0.221881476438683, 0.221881476438683, 0.171922134825388, 0.103629842929331, 3.91719822748777E-02];
Denominator: [1.000];
Can i use spectrogram function to plot and see the filter response? I have browse through the help file and could not find Parks-McClellan window. Anyone can help?
Regards, Newbie
0 件のコメント
採用された回答
Honglei Chen
2012 年 6 月 13 日
Parks-McClellan is an algorithm for filter design. It does not use window. Spectrogram is normally used to view the signal since it explores both time and frequency domain. You have a set of fixed filter coefficients so there is no time dependence. You can certainly use spectrogram, but it won't give you additional information than freqz does.
4 件のコメント
Honglei Chen
2012 年 6 月 13 日
That depends on what you plan to do. In general it is a trade off between the main beamwidth and sidelobe height. Different window gives different tradeoff, you should be able to find some discussions on windows on any DSP book. That being said, what is your application? There is nothing wrong to add a window to a filter designed by Parks-McClellan, but this may not preserve the the ripple behavior produced by Parks-McClellan. It may be better to include those requirement before using Parks-McClellan
Honglei Chen
2012 年 6 月 13 日
I'm not saying freqz is better. What I mean is that for a fixed set of filter coefficients, spectrogram will not give you more information than freqz since there is no time variation. If you want to see the impulse response of the filter, use impz
その他の回答 (3 件)
Wayne King
2012 年 6 月 13 日
You don't want to use spectrogram, use freqz()
freqz(FR_SV,1)
If you know the sampling frequency, you can input that as well. Here I will assume 10 kHz.
Fs = 1e4;
freqz(FR_SV,1,[],Fs)
0 件のコメント
Wayne King
2012 年 6 月 13 日
I'm not familiar with systemVue2009 so I cannot answer your question. In MATLAB, you can use FDATool
>>fdatool
to design a Parks-McClellan FIR equripple filter and export (save) the filter coefficients.