Derivative in simulink causes instability?!
6 ビュー (過去 30 日間)
古いコメントを表示
Hi all,
I have attached diagram of a simple system in simulink and I used Linearizing tool t extract the transfer function and its poles as shown in the figure. Any suggestion why this system is unstable? (I used a transfer function tf([N 1/N],[1 N])) instead of the derivative and its stable now.

Best regards Alireza
2 件のコメント
回答 (1 件)
Ravi Tripathi
2018 年 4 月 17 日
Please use a low pass filter after the derivative according to the signal frequency.