Derivative in simulink causes instability?!

Hi all,
I have attached diagram of a simple system in simulink and I used Linearizing tool t extract the transfer function and its poles as shown in the figure. Any suggestion why this system is unstable? (I used a transfer function tf([N 1/N],[1 N])) instead of the derivative and its stable now.
Best regards Alireza

2 件のコメント

Birdman
Birdman 2018 年 4 月 16 日
Can you share your model?
Alireza Sadri
Alireza Sadri 2018 年 4 月 17 日
Hi,
Sure, I have attached the block diagram in simulink, but these are all basic simulink elements and I am trying to show that what is happening to derivative block is far more than what is documented and I have no explanation for that, but I do have a solution as mentioned before.
Best regards Alireza

サインインしてコメントする。

回答 (1 件)

Ravi Tripathi
Ravi Tripathi 2018 年 4 月 17 日

0 投票

Please use a low pass filter after the derivative according to the signal frequency.

1 件のコメント

Alireza Sadri
Alireza Sadri 2018 年 4 月 17 日
Well as I mentioned, if I use tf([N a],[1 N]) and set a to a small positive number, the problem is solved. But I was looking for the reason behind this. Mabe the designer of the derivative should allow people to set a.

サインインしてコメントする。