is damp function got any limitation?

15 ビュー (過去 30 日間)
llca llasd
llca llasd 2018 年 4 月 8 日
コメント済み: llca llasd 2018 年 4 月 9 日
Hi,
fs =
3
-------------
s^2 + 3 s + 2
Continuous-time transfer function.
Pole Damping Frequency Time Constant
(rad/seconds) (seconds)
-1.00e+00 1.00e+00 1.00e+00 1.00e+00
-2.00e+00 1.00e+00 2.00e+00 5.00e-01
above are the result of my damp line, why my wn not √2 and damping not (3√2)/2 ? is there any limitation for damp function?

採用された回答

Birdman
Birdman 2018 年 4 月 8 日
I don't understand clearly your question, but the damping ratio and natural frequency can be found mathematically as follows:
It is known that an ideal second order transfer function is as follows:
K*Wn^2
------------------------
s^2 + 2*zeta*Wn*s + Wn^2
If we extract the coefficients of both transfer functions' denominator and solve for zeta and Wn,
2*zeta*wn=3
Wn^2=2;
From this, Wn is found as sqrt(2) and zeta(damping ratio) is found as 3/(2*sqrt(2)). This means zeta is greater than 1, which is normal since both poles are real, which will result in an overdamped step response. Hope this helps.
  3 件のコメント
Birdman
Birdman 2018 年 4 月 9 日
Oh, that is because damp function finds the damping ratio and frequency of the poles, not the system. What you want to find and what I showed you above is the damping ratio and natural frequency of the second order system. Please note the difference.
llca llasd
llca llasd 2018 年 4 月 9 日
Okay, thanks for clearing my doubt.

サインインしてコメントする。

その他の回答 (0 件)

カテゴリ

Help Center および File ExchangeSimulink についてさらに検索

タグ

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by