Why does the Simulink block mask initialization run twice?

8 ビュー (過去 30 日間)
Jason Nicholson
Jason Nicholson 2018 年 3 月 2 日
回答済み: Jason Nicholson 2018 年 3 月 21 日
If you are debugging a mask initialization, use the keyboard function to stop the code inside the Simulink block mask initialization. You'll notice that the mask is always run twice when a change is made to the mask. Why does the mask run twice?

採用された回答

Jason Nicholson
Jason Nicholson 2018 年 3 月 21 日
The initialization runs twice if "Icons & Ports"-->"Run initialization" is set to "On" or "Analyze" (assuming MATLAB detects the initialization needs to run). When the initialization runs twice, the order of execution seems to be:
  1. Run "Initialization"
  2. Run "Icons & Ports"
  3. Run "Initialization"

その他の回答 (0 件)

カテゴリ

Help Center および File ExchangeAuthor Block Masks についてさらに検索

タグ

製品

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by